Supermicro MicroCloud Solutions 3U 8-Node Xeon processor socket P
Mfg. Model Number:
Supermicro SYS-5039MP-H8TNR , black color.
RoHS Compliant
Key Features (per node)
Big Data Analytics
Cloud and Virtualization needs
Web Hosting, VM
Social Networking
CDN, Business Hosting
1. Single Socket P (LGA 3647) supports 2nd Gen. Intel® Xeon® Scalable processor (Cascade Lake/Skylake)
2. 2x 3.5" SATA3 by default; 2x 2.5" hybrid SATA3/NVMe w/ Optional kits
3. 4 DIMMs; up to 1TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM,
Supports Intel® Optane™ DCPMM††
4. 2 GbE LAN ports via Intel i350
5. 1 Centralized IPMI management port
6. 1 PCI-E 3.0 x16 (low-profile),
1 Micro-LP, and 2 M.2
7. 2 USB 2.0, 1 VGA, 1 COM port, (with KVM dongle)
8. 4x 8cm hot-swap cooling fans with fan speed control (per system)
9. 2200W Redundant Power Supplies Titanium Level Certified (per system)
Specifications:
|
Motherboard |
|
Super X11SPD-F |
|
|
Processor/Cache (per Node) |
|
CPU |
- Single Socket P (LGA 3647)
- 2nd Gen. Intel® Xeon® Scalable Processors (Cascade Lake/Skylake)‡
- Support CPU TDP 165W
|
Cores |
|
Note |
‡ BIOS version 3.0b or above is required to support 2nd Gen. Intel® Xeon® Scalable processors |
|
System Memory (per node) |
|
Memory Capacity |
- 4 DIMM slots
- Up to 1TB 3DS ECC DDR4-2933MHz† RDIMM/LRDIMM
- Supports Intel® Optane™ DCPMM††
|
Memory Type |
- 2933†/2666/2400/2133MHz ECC DDR4 RDIMM/LRDIMM
|
Note |
† 2933MHz in two DIMMs per channel can be achieved by using memory purchased from Supermicro
†† Cascade Lake only. Contact your Supermicro sales rep for more info. |
|
Network Devices (per node) |
|
Micro-LP NIC |
- Intel® i350 GbE LAN controller
- Dual RJ-45 connectors
- MicroLP Adapter Matrix (Networking options)
|
|
On-Board Devices (per node) |
|
Chipset |
|
SATA |
- SATA3 (6Gbps) via C621 controller
|
IPMI |
- Support for Intelligent Platform Management Interface v.2.0
- IPMI 2.0 with virtual media over LAN and KVM over LAN support
- ASPEED AST2500 BMC
|
Graphics |
- ASPEED AST2500 Graphics (BMC with Graphic controller)
|
|
Input / Output (per node) |
|
SATA |
|
LAN |
- 2 RJ45 Gigabit Ethernet LAN ports
|
KVM |
- 1 VGA, 1 COM and 2 USB 2.0 (with KVM dongle)
|
|
System BIOS |
|
BIOS Type |
- 128Mb SPI Flash EEPROM with AMI BIOS
|
BIOS Features |
- DMI 2.3
- ACPI 1.0 / 2.0
- USB Keyboard support
- SMBIOS 2.3
|
|
Management |
|
Software |
- Intel® Node Manager
- IPMI 2.0
- KVM with dedicated LAN
- SSM, SPM, SUM
- SuperDoctor® 5
- Watchdog
|
|
Rear Window (each node) |
|
Switch |
|
|
Chassis |
|
Form Factor |
|
Model |
|
|
Dimensions and Weight |
|
Height |
|
Width |
|
Depth |
|
Package |
- 11.65" (H) x 26.26" (W) x 34" (D)
|
Weight |
- Net Weight: 62.2 lbs (28.21 kg)
- Gross Weight: 88 lbs (39.92 kg)
|
Color |
|
|
Front Panel |
|
Buttons |
|
LEDs |
- Power LED
- Node status LED
|
|
Expansion Slots (per node) |
|
PCI-Express |
- 1 PCI-E 3.0 x16 (Low-profile) slot
- 1 Micro-LP PCI-E 3.0 x8 slot
|
M.2 |
- M.2 Interface: 2 SATA/PCI-E 3.0 x4
- M.2 Form Factor: 2280
- M.2 Key: M-Key
|
|
Drive Bays (per node) |
|
Internal |
- 2x 3.5" SATA3 (6Gbps) HDDs per node (or 2x 2.5" Hybrid SATA3/NVMe with optional kits); up to 16 HDDs total
- Enterprise SATA HDD only recommended
|
|
|
System Cooling |
|
Fans |
- 4 Hot-swap 8cm cooling fans fan speed control
|
|
Power Supply |
2200W Redundant Power Supplies with PMBus |
Total Output Power and Input |
- 1200W with Input 100-127Vac
- 1800W with Input 200-220Vac
- 1980W with Input 220-230Vac
- 2090W with Input 230-240Vac
- 2200W with Input 220-240Vac (for UL/cUL use only)
- 2090W with Input 230-240Vdc (for CCC only)
|
AC Input Frequency |
|
Dimension
(W x H x L) |
|
+12V |
- Max: 100A / Min: 0A (100-127Vac)
- Max: 150A / Min: 0A (200-220Vac)
- Max: 165A / Min: 0A (220-230Vac)
- Max: 174.17A / Min: 0A (230-240Vac)
- Max: 183.3A / Min: 0A (220-240Vac)
|
5VSB |
|
Output Type |
|
Certification |
 Titanium Level
[ Test Report ] |
|
PC Health Monitoring |
|
CPU |
- Monitors for CPU Cores, +3.3V, +5V, +12V, +3.3V Standby, +5V Standby, VBAT, Memory, Chipset Voltages.
- 5 Phase-switching voltage regulator with auto-sense from 0.8375V-1.60V
|
FAN |
|
Temperature |
- Monitoring for CPU and chassis environment
|
|
Operating Environment / Compliance |
|
RoHS
|
|
Environmental Spec. |
- Operating Temperature:
10°C to 35°C (50°F to 95°F)
- Non-operating Temperature:
-40°C to 70°C (-40°F to 158°F)
- Operating Relative Humidity:
8% to 90% (non-condensing)
- Non-operating Relative Humidity:
5% to 95% (non-condensing)
|
|
Parts List
|
Parts List - (Items Included) |
|
|
Part Number
|
Qty
|
Description
|
Motherboard / Chassis |
MBD-X11SPD-F
CSE-938NH-R2K20BP |
8
1 |
Super X11SPD-F Motherboard
3U Chassis |
Add-on Card / Module |
AOC-CGP-I2-P |
8 |
AOC-CGP-I2-O-P |
Add-on Card / Module |
AOM-BPN-938NH-P |
1 |
AOM-BPN-938NH, Backplane module for 8-node Microcloud system, 16xU.2, 2 per node, Dual PSU, Management LAN switch, chassis node ID.,HF,RoHS |
Add-on Card / Module |
AOM-LAN-MC8-P |
1 |
AOM-LAN-MC8, LAN front panel module for 8-node Microcloud system,HF,RoHS |
Add-on Card / Module |
AOM-PDB-PT938-LSG-P |
1 |
AOM-PDB-PT938-LSG, PDB module for 8-node Microcloud system,HF,RoHS |
Add-on Card / Module |
AOM-PDB-PT938-RSG-P |
1 |
AOM-PDB-PT938-RSG, PDB module for 8-node Microcloud system,HF,RoHS |
Cable 1 |
CBL-0218L |
1 |
USB/KVM/SUVI,36 PIN TO 9 PIN/15 PIN/2 USB CH,11.5CM,30/28AWG |
Cable 2 |
CBL-0355L |
2 |
ETHERNET,CAT5E,RJ45 W/BOOT,GREEN,UTP,2FT (60CM),24AWG |
Cable 3 |
CBL-0458L |
1 |
20 cm 30 pin to 30 pin Front control cable with tube. 28AWG |
Cable 4 |
CBL-CDAT-0662 |
1 |
CBL,SGPIO,2X4F TO 2X4F,P2.54,ROUND CABLE,61.5CM,28AWG |
Cable 5 |
CBL-PWCD-0578 |
2 |
PWCD,US,IEC60320 C14 TO C13,3FT,14AWG |
FAN 1 |
FAN-0194L4 |
4 |
80x80x38 mm, 13.5K RPM Cooling Fan for 3U8N Microcloud Serie |
Drive Tray(s) |
MCP-220-00094-0B |
16 |
Black gen 6.5 hot-swap 3.5 inch HDD Tray |
Air Shroud |
MCP-310-93805-0B |
16 |
Mylar air shroud for 2-DIMMs (quick install on DIMM latch) |
Power Supply |
PWS-2K20A-1R |
2 |
2200W Redundant, Titanium, 76(W) X 40(H) X 336(L) mm |
Riser Card |
RSC-RR1U-E16 |
8 |
RSC-RR1U-E16 with PIC-E x16 output |
|
Optional Parts List |
|
|
Part Number |
Qty |
Description |
TPM security module |
AOM-TPM-9670V |
1 |
SPI capable TPM 2.0 with Infineon 9670 controller,
Vertical form factor |
TPM security module |
AOM-TPM-9671V |
1 |
SPI capable TPM 1.2 with Infineon 9670 controller,
Vertical form factor |
Intel VROC RAID Key |
AOC-VROCINTMOD
AOC-VROCSTNMOD
AOC-VROCPREMOD |
1
1
1 |
Intel VROC, RAID 0, 1, 5, 10 (Intel SSD Only)
Intel VROC Standard, RAID 0, 1, 10
Intel VROC Premium, RAID 0, 1, 5, 10 |
Cable |
CBL-SAST-0610 |
- |
For AOC-S3008L-L8i/AOC-S3108L-H8IR |
Storage Controller Card(s) |
AOC-S3008L-L8i
AOC-S3108L-H8IR
AOC-S3108L-H8IR-16DD |
- |
Std LP, 8 ports, 12Gb/s Gen3, RAID 0/1/10
Std LP, 8 ports, 12Gb/s Gen3, RAID 0/1/5/6/10/50/60
Std LP, 8 ports, 12Gb/s Gen3, RAID 0/1/5/6/10/50/60 |
Network Card(s) |
AOC-CTGS-i2T
AOC-CTG-i1S
AOC-CTG-i2S
AOC-C25G-m1S
AOC-S40G-i2Q
AOC-SGP-i2
AOC-SGP-i4
AOC-STG-i2
AOC-STG-i2T
AOC-STGN-i1S
AOC-STGN-i2S
AOC-S100G-m2C
AOC-SHFI-I1C |
- |
MicroLP, 2x 10GbE Base-T, PCI-E 3.0 x4, Intel® X550
MicroLP, 1 x 10GbE SFP+, PCI-E 2.0 x8, Intel® 82599EN
MicroLP, 2 x 10GbE SFP+, PCI-E 2.0 x8, Intel® 82599EN
MicroLP, 1x 25GbE SFP28 port, Mellanox® ConnectX-4 Lx EN
Standard LP 2-port 40GbE controller, Intel Fortville XL710
Standard LP, 2x GbE RJ45, PCI-E x4, Intel i350AM2
Standard LP, 4x GbE RJ45, PCI-E x4, Intel i350
Standard LP, 2x 10GbE CX4, PCI-E x8, Intel 82598EB
Standard LP, 2x 10GbE RJ45, PCI-E x8, Intel X540
Standard LP, 1x 10GbE SFP+, PCI-E x8, Intel 82599EN
Standard LP, 2x 10GbE SFP+, PCI-E x8, Intel 82599ES
Standard LP 2-port 100GbE with 2 QSFP28, Mellanox CX-4 EN
Standard LP 1-port Omni Path controller, Intel 100HFA016LS |
Drive Tray(s) |
MCP-220-93801-0B |
- |
Black gen 6 hot-swap 3.5-to-2.5 HDD tray |
Drive Tray(s) |
MCP-220-00158-0B |
- |
Black gen 6.5 hot-swap 3.5-to-2.5 Tool-less drive tray |
Global Services & Support |
OS4HR3/2/1
OSNBD3/2/1 |
-
- |
3/2/1-year onsite 24x7x4 service
3/2/1-year onsite NBD service |
Software |
SFT-OOB-LIC •  |
1 |
OOB Management Package (per node license) |
Software |
SFT-DCMS-Single |
1 |
DataCenter Management Package (per node license) |